Kenilworth Outfall Sewer
 
		Approached by West Point Construction in 2020 to carry out specialist works required to construct a storm outfall for housing development, The Pavillions, being constructed by the Vistry Group.
The 5.85ha site is located on the east side of the Warwick Road and will be utilised for 125 residential houses. Rorcon picked up the contract for the tunnelled connection into the live sewer formation with groundwater present at depths between 1.74m and 2.69m.
To meet the upmost standard of health and safety, Rorcon innovatively designed the project to remove the need for extra concrete breaking thus resulting in a reduction of hazards which ultimately contributed to the project having zero incidents or injuries. Something we take seriously on all of our projects.
The 9m deep, 4.5m diameter, segmentally lined shaft was constructed by the underpinning method. Knowing the rock was hard sandstone that contained angular to rounded line coarse gravel, Rorcon went against the ‘conventional’ hand mining methods Rorcon proposed an outline scheme using both mechanised mining and full steel square work to take the concept forward.
The team used a combination of a Brokk 160 demolition robot and a mini digger to load the muck skip.
Our ethos of sharing mutual success is at the heart of everything we do, achieved by providing committed people, delivering successful projects and achieving high levels of performance.
 
		After the shaft was completed, the gang drove a 1.5x 1.5m square heading, 15m in length, which was excavated using a Brokk 70 with a Bob Cat MT55 Skid Steer Loader for muck removal. The heading was driven underneath Warwick Road and formed a connection into the existing sewer.
 
		 
		